Running uf cable through metal or pvc conduit.
Underground power cable conduit.
The national electrical code nec recommends a maximum voltage drop of 3 percent for individual household circuits known as branch circuits this is a good goal to shoot for when sizing the conductors for an underground cable the following are the maximum lengths of cable you can use while still maintaining a 3 percent voltage drop for the given wire size awg and.
Find the type of conduit that you want to use in table 4.
Electrical cable depth options.
Push a length of uf underground feed electrical cable into the conduit then feed the end of the cable through the hole in the house wall.
Flexible metallic conduit bends and twists easily allowing turns at corners without the use of elbow joints.
Deep pvc conduit method we show is about the easiest and most practical for running a typical 15 amp line.
Owing to the durability of rigid metal conduit you can bury electrical wire in this conduit at a shallower depth.
If necessary use a propane powered heat gun to bend the conduit to conform to the foundation.
Secure the cable to the overhead joists with cable staples.
Nec 300 5 underground wiring conduit movement protection where subject to movement direct buried cables or raceways shall be arranged to prevent damage to the enclosed conductors or connected equipment.
Attach a plastic conduit outlet body to the end of the conduit.
Underground cable for running electrical power to a remote location can be installed at different depths depending on the type of conduit and type of wire used.
There are several different methods for safely running the underground wiring but the 12 in.
Push a length of uf underground feed electrical cable into the conduit then feed the end of the cable through the hole in the house wall.
But it can be difficult to fish cable through conduit unless the conduit is at least 3 4 inch in diameter.
Metal electrical boxes must be used with metal conduit.
Nec 300 5 underground wiring conduits emerging from the ground conductors emerging from underground shall be installed in rigid metal conduit.
Electrical wire in rigid metal conduit.
However keep in mind that no cable or conduit is protected from digging by construction equipment such as trench diggers or backhoes.
Although not commonly done it is allowable to run uf cable but not nm cable through metal or pvc conduit in an underground application.
If you re using electrical metal tubing emt conduit you ll see that the closest size that you need is a 1 in conduit which gives you a 39 fill.
Decide how much digging you re prepared to do which determines the type of wire you need to use.
Sizing the conductors.
From inside the basement pull the cable all the way to the main electrical panel.
Conduit cable fill chart this chart for conduit size for cable is based on the 2017 nec and uses common conduit types and wires.
If you need to install an outdoor electrical outlet because you need to power a pond pump or other device think safety.